crazyweblist.com crazyweblist.com
   Main About Us Privacy of Info Terms of Use Add Url Add Article
Search:   
 
 

Are You Losing Sales Because of These 4 Simple Website Mistakes?

Losing website sales and traffic is sometimes simply a case of web usablity - your website just isn' ... - Kate Fox
 

How To Create Your Own Successful And Profitable Affiliate Program

Most of the truly successful marketers have three competitive advantages : They run successful Affil ... - Charles Kangethe
 

Sender Policy Framework (SPF) - How to use it to Fight Email Forgery

Spam is a real problem today. Forged email is a big part of the spam problem. Have you ever received ... - Joe Duchesne
 
 

Domain Names 101 - A Dummies Guide to Choosing Great Domain Names

There are several things you can do to ensure you choose the best type of domain for your business, ... - Michael Turner
 

Search Engine Optimization with Article Marketing

Does article marketing really work for page rank and search engine ranking? Find out what I think! - Sean Mize
 
 

Main » Internet & Computers » Hardware Peripherals
 

Four Power System Problems Common in Colocation Facilities

 

Author: Robert Deupree

The primary factor that determines uptime for servers in a colocation facility is power. Power outages will knock a network offline and even damage hardware such as motherboards, memory, and hard drives. Despite how intrinsic power is to keeping businesses connected to their networks, only 2% to 3% of colocation facilities have the right power systems in place. The other 97% of facilities most commonly lack redundancy, multiple units carry the energy load even if one unit fails, or have units that are running above capacity, so a unit failure will cause the other units to overload and fail. Every part of the power system uninterruptible power supplies (UPS), transfer switches or circuit breakers, generators, and power distribution units (PDU) should be redundant and running below capacity.

Problem 1: Non-redundant Power Grids
Multiple PDUs connected to separate power grids and multiple UPSs should be designed into the colocation facility to offset a power grid failure. Colocation facilities with redundant power grids can connect customer servers to different grids at the same time, so that even if one goes offline, the other will work, keeping the network running without interruption.

Problem 2: Non-redundant UPSs
The UPSs supply power during an outage until the generator can come online; if the UPSs do not turn on immediately at the time of failure, then the network will go down. Even with high quality UPSs, failures are common, so it is critical for there to be multiple redundant UPS units in an n+1 configuration all of the necessary UPSs, plus an extra. Functionally, this means that each UPS runs sufficiently below capacity to handle a unit failure without the other units overloading. If there are two UPSs, then each unit must run below 50%, so that if one fails, the other can continue without overloading. If there are three units, each must run below 66%; four units, below 75%. The current load is shown on the display on the front of the UPS.

Problem 3: Transfer Switch Failures
Most colocation facilities use mechanical transfer switches, which are not as dependable as circuit breakers, to switch power from the electric utility to the generator. These switches are one of the most common places the power system fails. Without redundant switches to transfer power at the same point, a transfer switch failure will mean that a network goes down.

Problem 4: Insufficient Generator Capacity
Generators supply power during an outage. To run without overloading, the generator must have capacity to run 1.5 times the total building load. Ideally, a colocation facility should have a redundant backup generator in case the primary generator fails, and the facility should have a process in place for switching power between generators. Having multiple generators is not the same as having redundant generators. One of the most common generator problems with colocation facilities is that the facility started out with a small generator and added generators as it grew. This creates multiple points where power has to be transferred during an outage, increasing the likelihood that a network will go down. As a practical consideration, the generators must be well-maintained, tested monthly, and fully supplied with fuel.

Points to Consider
Fewer than one in twenty colocation facilities have the best power systems in place despite the fact that power systems have the most impact on network uptime. Without well-maintained and redundant components running below capacity at every part of the system, network performance as well as server performance and equipment lifetime will suffer. To make sure that the power system at a colocation facility is robust enough to handle power and equipment failures, two words should be remembered: capacity and redundancy.

Author Bio:
Robert Deupree is a reputable writer. Robert likes to scribble articles about this industry.
You can also reach this article by using: computer hardware, pc hardware, computer hardware review, computer hardware supplier
 
 
 

Related Articles

 
4 Steps to Laser Precise Ad Tracking & Budget Management
 
Discount Linux Web Hosting
 
Forums Drive Traffic To Your New Website
 
List Building 101 - An Introduction To List Building
 
Blogging Can Help You Stick to That New Year's Resolution
 
Domain Name Appraisal Information
 
Introducing the Power of Autoresponders
 
Don't Make Your Computer A Target When It Comes To Physical Security
 
Learn Simple Strategies That Will Stop Spammers From Bombarding Your Inbox!
 
EyeTrack III - Can It Really SEE Your Visitors Thought Paterns?
 
 
 
 

Self Enhancement

 

Medicine & Treatment

 

Science & Research

 

Teens & Children

 

Fitness & Health

 

Tour & Travel

 

Companies & Business

 

Outdoor & Sports

 

Jobs & Employment

 

Automobile & Automotive

 

Property & Estate

 

Music & Entertainment

 

People & Communities

 

Culture & Art

 

Lifestyle & Fashion

 

Internet & Computers

 

Policies & Law

 

Events & News

 

Home & Garden

 

Games & Play

 

Education & Reference

 

Shopping Online

 

Food & Recipe

 

Finance & Investment

 
Main Privacy of Info Terms of Use  
© 2006 www.crazyweblist.com - All Rights Reserved